• Human PPIB (Peptidyl-prolyl cis-trans isomerase B) CLIA Kit (STJC0000842)

Human PPIB (Peptidyl-prolyl cis-trans isomerase B) CLIA Kit (STJC0000842)

SKU:
STJC0000842

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This human PPIB kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: PPIB
Gene ID: 5479
Uniprot ID: PPIB_HUMAN
Specificity: This kit recognizes Human CYPB in samples. No significant cross-reactivity or interference between Human CYPB and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function PPIase that catalyzes the cis-trans isomerization of proline imidic peptide bonds in oligopeptides and may therefore assist protein folding.
Protein Name Peptidyl-Prolyl Cis-Trans Isomerase B
Ppiase B
Cyp-S1
Cyclophilin B
Rotamase B
S-Cyclophilin
Scylp
Database Links Reactome: R-HSA-1650814
Reactome: R-HSA-9692916
Cellular Localisation Virion
(Microbial Infection)
Endoplasmic Reticulum Lumen
Melanosome
Identified By Mass Spectrometry In Melanosome Fractions From Stage I To Stage Iv
Alternative CLIA Names Peptidyl-Prolyl Cis-Trans Isomerase B CLIA kit
Ppiase B CLIA kit
Cyp-S1 CLIA kit
Cyclophilin B CLIA kit
Rotamase B CLIA kit
S-Cyclophilin CLIA kit
Scylp CLIA kit
PPIB CLIA kit
CYPB CLIA kit
Specificity This kit recognizes Human CYPB in samples. No significant cross-reactivity or interference between Human CYPB and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 92-106 99
EDTA plasma(n=8) 84-97 91
Cell culture media(n=8) 96-111 102

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 200.60 418.99 1835.95 186.21 405.29 1704.59
Standard deviation 22.67 41.27 144.31 16.57 48.43 114.04
CV (%) 11.30 9.85 7.86 8.90 11.95 6.69
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance