• Human PKP1 (Plakophilin-1) CLIA Kit (STJC0000918)

Human PKP1 (Plakophilin-1) CLIA Kit (STJC0000918)

SKU:
STJC0000918

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This human PKP1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: PKP1
Gene ID: 5317
Uniprot ID: PKP1_HUMAN
Specificity: This kit recognizes Human PKP1 in samples. No significant cross-reactivity or interference between Human PKP1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Isoform 1: Expressed in stratified squamous, complex, glandular duct and bladder epithelia (at protein level). Isoform 2: Widely expressed (at protein level).
Function Seems to play a role in junctional plaques. Contributes to epidermal morphogenesis. May facilitate the formation of intermediate filaments.
Protein Name Plakophilin-1
Band 6 Protein
B6p
Database Links Reactome: R-HSA-351906
Reactome: R-HSA-6798695
Reactome: R-HSA-6805567
Reactome: R-HSA-6809371
Cellular Localisation Isoform 1: Cell Junction
Desmosome
Isoform 2: Nucleus
Nucleus
Alternative CLIA Names Plakophilin-1 CLIA kit
Band 6 Protein CLIA kit
B6p CLIA kit
PKP1 CLIA kit
Specificity This kit recognizes Human PKP1 in samples. No significant cross-reactivity or interference between Human PKP1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 92-107 99
EDTA plasma(n=8) 97-110 104
Cell culture media(n=8) 90-101 96

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 183.04 560.29 1509.07 190.29 595.18 1423.00
Standard deviation 22.99 62.30 108.20 22.70 58.51 111.56
CV (%) 12.56 11.12 7.17 11.93 9.83 7.84
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance