Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
18.75pg/mL |
Detection Limit: |
31.25~2000pg/mL |
Short Description: |
This human PDIA6 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
PDIA6 |
Gene ID: |
10130 |
Uniprot ID: |
PDIA6_HUMAN |
Specificity: |
This kit recognizes Human PDIA6 in samples. No significant cross-reactivity or interference between Human PDIA6 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Expressed in platelets (at protein level). |
Function | May function as a chaperone that inhibits aggregation of misfolded proteins. Negatively regulates the unfolded protein response (UPR) through binding to UPR sensors such as ERN1, which in turn inactivates ERN1 signaling. May also regulate the UPR via the EIF2AK3 UPR sensor. Plays a role in platelet aggregation and activation by agonists such as convulxin, collagen and thrombin. |
Protein Name | Protein Disulfide-Isomerase A6Endoplasmic Reticulum Protein 5Er Protein 5Erp5Protein Disulfide Isomerase P5Thioredoxin Domain-Containing Protein 7 |
Database Links | Reactome: R-HSA-381038Reactome: R-HSA-381426Reactome: R-HSA-8957275 |
Cellular Localisation | Endoplasmic Reticulum LumenCell MembraneMelanosomeIdentified By Mass Spectrometry In Melanosome Fractions From Stage I To Stage Iv |
Alternative CLIA Names | Protein Disulfide-Isomerase A6 CLIA kitEndoplasmic Reticulum Protein 5 CLIA kitEr Protein 5 CLIA kitErp5 CLIA kitProtein Disulfide Isomerase P5 CLIA kitThioredoxin Domain-Containing Protein 7 CLIA kitPDIA6 CLIA kitERP5 CLIA kitP5 CLIA kitTXNDC7 CLIA kit |
Specificity | This kit recognizes Human PDIA6 in samples. No significant cross-reactivity or interference between Human PDIA6 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 86-98 | 93 |
EDTA plasma(n=8) | 91-106 | 97 |
Cell culture media(n=8) | 95-113 | 103 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 93.48 | 269.54 | 931.70 | 100.71 | 269.13 | 861.43 |
Standard deviation | 9.41 | 22.10 | 57.95 | 11.65 | 26.99 | 60.90 |
CV (%) | 10.07 | 8.20 | 6.22 | 11.57 | 10.03 | 7.07 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance