• Human MUC21 (Mucin-21) CLIA Kit (STJC0000367)

Human MUC21 (Mucin-21) CLIA Kit (STJC0000367)

SKU:
STJC0000367

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human MUC21 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: MUC21
Gene ID: 394263
Uniprot ID: MUC21_HUMAN
Specificity: This kit recognizes Human MUC21 in samples. No significant cross-reactivity or interference between Human MUC21 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed in lung, large intestine, thymus, and testis. Expressed in normal and malignant bronchial epithelial cells.
Post Translational Modifications O-glycosylated.
Protein Name Mucin-21
Muc-21
Epiglycanin
Database Links Reactome: R-HSA-5083625
Reactome: R-HSA-5083632
Reactome: R-HSA-5083636
Reactome: R-HSA-5621480
Reactome: R-HSA-913709
Reactome: R-HSA-977068
Cellular Localisation Cell Membrane
Single-Pass Type I Membrane Protein
Extracellular Side
Alternative CLIA Names Mucin-21 CLIA kit
Muc-21 CLIA kit
Epiglycanin CLIA kit
MUC21 CLIA kit
C6orf205 CLIA kit
UNQ697 CLIA kit
PRO1342 CLIA kit
Specificity This kit recognizes Human MUC21 in samples. No significant cross-reactivity or interference between Human MUC21 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 88-103 94
EDTA plasma(n=8) 93-108 100
Cell culture media(n=8) 94-106 101

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 99.37 317.37 892.17 95.71 316.23 868.62
Standard deviation 12.77 34.12 97.87 7.83 34.88 56.29
CV (%) 12.85 10.75 10.97 8.18 11.03 6.48
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance