• Human LOXL4 (Lysyl oxidase homolog 4) CLIA Kit (STJC0000992)

Human LOXL4 (Lysyl oxidase homolog 4) CLIA Kit (STJC0000992)

SKU:
STJC0000992

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This human LOXL4 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: LOXL4
Gene ID: 84171
Uniprot ID: LOXL4_HUMAN
Specificity: This kit recognizes Human LOXL4 in samples. No significant cross-reactivity or interference between Human LOXL4 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed in many tissues, the highest levels among the tissues studied being in the skeletal muscle, testis and pancreas. Expressed in cartilage.
Post Translational Modifications The lysine tyrosylquinone cross-link (LTQ) is generated by condensation of the epsilon-amino group of a lysine with a topaquinone produced by oxidation of tyrosine.
Function May modulate the formation of a collagenous extracellular matrix.
Protein Name Lysyl Oxidase Homolog 4
Lysyl Oxidase-Like Protein 4
Lysyl Oxidase-Related Protein C
Database Links Reactome: R-HSA-1566948
Reactome: R-HSA-2243919
Cellular Localisation Secreted
Extracellular Space
Alternative CLIA Names Lysyl Oxidase Homolog 4 CLIA kit
Lysyl Oxidase-Like Protein 4 CLIA kit
Lysyl Oxidase-Related Protein C CLIA kit
LOXL4 CLIA kit
LOXC CLIA kit
Specificity This kit recognizes Human LOXL4 in samples. No significant cross-reactivity or interference between Human LOXL4 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 97-111 105
EDTA plasma(n=8) 91-106 97
Cell culture media(n=8) 102-117 108

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 206.00 440.71 1829.87 222.42 418.65 1930.02
Standard deviation 16.87 46.63 118.58 22.69 39.06 196.09
CV (%) 8.19 10.58 6.48 10.20 9.33 10.16
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance