• Human LGALS4 (Galectin-4) CLIA Kit (STJC0000505)

Human LGALS4 (Galectin-4) CLIA Kit (STJC0000505)

SKU:
STJC0000505

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This human LGALS4 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: LGALS4
Gene ID: 3960
Uniprot ID: LEG4_HUMAN
Specificity: This kit recognizes Human GAL4 in samples. No significant cross-reactivity or interference between Human GAL4 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Galectin that binds lactose and a related range of sugars. May be involved in the assembly of adherens junctions.
Protein Name Galectin-4
Gal-4
Antigen Ny-Co-27
L-36 Lactose-Binding Protein
L36lbp
Lactose-Binding Lectin 4
Alternative CLIA Names Galectin-4 CLIA kit
Gal-4 CLIA kit
Antigen Ny-Co-27 CLIA kit
L-36 Lactose-Binding Protein CLIA kit
L36lbp CLIA kit
Lactose-Binding Lectin 4 CLIA kit
LGALS4 CLIA kit
Specificity This kit recognizes Human GAL4 in samples. No significant cross-reactivity or interference between Human GAL4 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 91-103 96
EDTA plasma(n=8) 92-106 98
Cell culture media(n=8) 86-100 92

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 192.11 625.53 1530.50 188.76 587.59 1435.41
Standard deviation 15.75 63.18 118.77 21.88 64.69 93.59
CV (%) 8.20 10.10 7.76 11.59 11.01 6.52
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance