Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
9.38pg/mL |
Detection Limit: |
15.63~1000pg/mL |
Short Description: |
This human KITLG kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
KITLG |
Gene ID: |
4254 |
Uniprot ID: |
SCF_HUMAN |
Specificity: |
This kit recognizes Human SCF in samples. No significant cross-reactivity or interference between Human SCF and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Post Translational Modifications | A soluble form (sKITLG) is produced by proteolytic processing of isoform 1 in the extracellular domain. Found in two differentially glycosylated forms, LMW-SCF and HMW-SCF. LMW-SCF is fully N-glycosylated at Asn-145, partially N-glycosylated at Asn-90, O-glycosylated at Ser-167, Thr-168 and Thr-180, and not glycosylated at Asn-97 or Asn-118. HMW-SCF is N-glycosylated at Asn-118, Asn-90 and Asn-145, O-glycosylated at Ser-167, Thr-168 and Thr-180, and not glycosylated at Asn-97. A soluble form exists as a cleavage product of the extracellular domain. |
Function | Ligand for the receptor-type protein-tyrosine kinase KIT. Plays an essential role in the regulation of cell survival and proliferation, hematopoiesis, stem cell maintenance, gametogenesis, mast cell development, migration and function, and in melanogenesis. KITLG/SCF binding can activate several signaling pathways. Promotes phosphorylation of PIK3R1, the regulatory subunit of phosphatidylinositol 3-kinase, and subsequent activation of the kinase AKT1. KITLG/SCF and KIT also transmit signals via GRB2 and activation of RAS, RAF1 and the MAP kinases MAPK1/ERK2 and/or MAPK3/ERK1. KITLG/SCF and KIT promote activation of STAT family members STAT1, STAT3 and STAT5. KITLG/SCF and KIT promote activation of PLCG1, leading to the production of the cellular signaling molecules diacylglycerol and inositol 1,4,5-trisphosphate. KITLG/SCF acts synergistically with other cytokines, probably interleukins. |
Protein Name | Kit LigandMast Cell Growth FactorMgfStem Cell FactorScfC-Kit Ligand Cleaved Into - Soluble Kit LigandSkitlg |
Database Links | Reactome: R-HSA-1257604 P21583-1Reactome: R-HSA-1433557 P21583-1Reactome: R-HSA-1433559 P21583-1Reactome: R-HSA-2219530 P21583-1Reactome: R-HSA-5673001 P21583-1Reactome: R-HSA-6811558 P21583-1 |
Cellular Localisation | Isoform 1: Cell MembraneSingle-Pass Type I Membrane ProteinIsoform 2: CytoplasmCytoplasmCytoskeletonCell MembraneCell ProjectionLamellipodiumFilopodiumSoluble Kit Ligand: Secreted |
Alternative CLIA Names | Kit Ligand CLIA kitMast Cell Growth Factor CLIA kitMgf CLIA kitStem Cell Factor CLIA kitScf CLIA kitC-Kit Ligand Cleaved Into - Soluble Kit Ligand CLIA kitSkitlg CLIA kitKITLG CLIA kitMGF CLIA kitSCF CLIA kit |
Specificity | This kit recognizes Human SCF in samples. No significant cross-reactivity or interference between Human SCF and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 91-105 | 98 |
EDTA plasma(n=8) | 93-105 | 100 |
Cell culture media(n=8) | 88-102 | 93 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 52.31 | 133.07 | 424.59 | 52.42 | 140.94 | 385.49 |
Standard deviation | 5.26 | 10.22 | 42.59 | 5.23 | 12.15 | 25.44 |
CV (%) | 10.06 | 7.68 | 10.03 | 9.98 | 8.62 | 6.60 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance