Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.19ng/mL |
Detection Limit: |
0.31~20ng/mL |
Short Description: |
This human HSP-60/HSPD1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
HSPD1 |
Gene ID: |
3329 |
Uniprot ID: |
CH60_HUMAN |
Specificity: |
This kit recognizes Human HSP-60/HSPD1 in samples. No significant cross-reactivity or interference between Human HSP-60/HSPD1 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Function | Chaperonin implicated in mitochondrial protein import and macromolecular assembly. Together with Hsp10, facilitates the correct folding of imported proteins. May also prevent misfolding and promote the refolding and proper assembly of unfolded polypeptides generated under stress conditions in the mitochondrial matrix. The functional units of these chaperonins consist of heptameric rings of the large subunit Hsp60, which function as a back-to-back double ring. In a cyclic reaction, Hsp60 ring complexes bind one unfolded substrate protein per ring, followed by the binding of ATP and association with 2 heptameric rings of the co-chaperonin Hsp10. This leads to sequestration of the substrate protein in the inner cavity of Hsp60 where, for a certain period of time, it can fold undisturbed by other cell components. Synchronous hydrolysis of ATP in all Hsp60 subunits results in the dissociation of the chaperonin rings and the release of ADP and the folded substrate protein (Probable). |
Protein Name | 60 Kda Heat Shock Protein - Mitochondrial60 Kda ChaperoninChaperonin 60Cpn60Heat Shock Protein 60Hsp-60Hsp60Hucha60Mitochondrial Matrix Protein P1P60 Lymphocyte Protein |
Database Links | Reactome: R-HSA-1268020Reactome: R-HSA-8869496 |
Cellular Localisation | Mitochondrion Matrix |
Alternative CLIA Names | 60 Kda Heat Shock Protein - Mitochondrial CLIA kit60 Kda Chaperonin CLIA kitChaperonin 60 CLIA kitCpn60 CLIA kitHeat Shock Protein 60 CLIA kitHsp-60 CLIA kitHsp60 CLIA kitHucha60 CLIA kitMitochondrial Matrix Protein P1 CLIA kitP60 Lymphocyte Protein CLIA kitHSPD1 CLIA kitHSP60 CLIA kit |
Specificity | This kit recognizes Human HSP-60/HSPD1 in samples. No significant cross-reactivity or interference between Human HSP-60/HSPD1 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 98-114 | 106 |
EDTA plasma(n=8) | 97-113 | 104 |
Cell culture media(n=8) | 95-110 | 102 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 1.05 | 2.60 | 6.78 | 1.11 | 2.80 | 6.83 |
Standard deviation | 0.12 | 0.29 | 0.44 | 0.11 | 0.33 | 0.52 |
CV (%) | 11.43 | 11.15 | 6.49 | 9.91 | 11.79 | 7.61 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance