Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
37.5pg/mL |
Detection Limit: |
62.5~4000pg/mL |
Short Description: |
This human HHIP kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
HHIP |
Gene ID: |
64399 |
Uniprot ID: |
HHIP_HUMAN |
Specificity: |
This kit recognizes Human HHIP in samples. No significant cross-reactivity or interference between Human HHIP and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Widely expressed in fetal and adult tissues. Highest expression in adult heart, liver and pancreas, and in fetal kidney. |
Function | Modulates hedgehog signaling in several cell types including brain and lung through direct interaction with members of the hedgehog family. |
Protein Name | Hedgehog-Interacting ProteinHhipHip |
Database Links | Reactome: R-HSA-5632681 |
Cellular Localisation | Cell MembranePeripheral Membrane ProteinSecretedThe Last 22 C-Terminal Amino Acids May Participate In Cell Membrane AttachmentIsoform 2: Cytoplasm |
Alternative CLIA Names | Hedgehog-Interacting Protein CLIA kitHhip CLIA kitHip CLIA kitHHIP CLIA kitHIP CLIA kitUNQ5825 CLIA kitPRO19644 CLIA kit |
Specificity | This kit recognizes Human HHIP in samples. No significant cross-reactivity or interference between Human HHIP and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 100-116 | 106 |
EDTA plasma(n=8) | 88-99 | 94 |
Cell culture media(n=8) | 89-102 | 94 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 204.06 | 625.68 | 1486.17 | 197.49 | 637.73 | 1348.08 |
Standard deviation | 19.86 | 74.96 | 95.26 | 15.98 | 49.42 | 112.70 |
CV (%) | 9.73 | 11.98 | 6.41 | 8.09 | 7.75 | 8.36 |