• Human GP5 (Platelet glycoprotein V) CLIA Kit (STJC0000853)

Human GP5 (Platelet glycoprotein V) CLIA Kit (STJC0000853)

SKU:
STJC0000853

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.19ng/mL
Detection Limit: 0.31~20ng/mL
Short Description: This human GP5 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: GP5
Gene ID: 2814
Uniprot ID: GPV_HUMAN
Specificity: This kit recognizes Human GP5 in samples. No significant cross-reactivity or interference between Human GP5 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Platelets and megakaryocytes.
Post Translational Modifications The N-terminus is blocked.
Function The GPIb-V-IX complex functions as the vWF receptor and mediates vWF-dependent platelet adhesion to blood vessels. The adhesion of platelets to injured vascular surfaces in the arterial circulation is a critical initiating event in hemostasis.
Protein Name Platelet Glycoprotein V
Gpv
Glycoprotein 5
Cd Antigen Cd42d
Database Links Reactome: R-HSA-140837
Reactome: R-HSA-430116
Reactome: R-HSA-75892
Reactome: R-HSA-76009
Reactome: R-HSA-9673221
Cellular Localisation Membrane
Single-Pass Type I Membrane Protein
Alternative CLIA Names Platelet Glycoprotein V CLIA kit
Gpv CLIA kit
Glycoprotein 5 CLIA kit
Cd Antigen Cd42d CLIA kit
GP5 CLIA kit
Specificity This kit recognizes Human GP5 in samples. No significant cross-reactivity or interference between Human GP5 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 83-95 90
EDTA plasma(n=8) 96-110 104
Cell culture media(n=8) 85-98 90

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 0.98 1.68 9.11 1.07 1.79 8.62
Standard deviation 0.08 0.15 0.82 0.13 0.18 0.66
CV (%) 8.16 8.93 9.00 12.15 10.06 7.66