• Human GKN2 (Gastrokine-2) CLIA Kit (STJC0000868)

Human GKN2 (Gastrokine-2) CLIA Kit (STJC0000868)

SKU:
STJC0000868

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 7.5pg/mL
Detection Limit: 12.5~800pg/mL
Short Description: This human GKN2 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: GKN2
Gene ID: 200504
Uniprot ID: GKN2_HUMAN
Specificity: This kit recognizes Human GKN2 in samples. No significant cross-reactivity or interference between Human GKN2 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed in gastric mucosa.
Protein Name Gastrokine-2
Blottin
Down-Regulated In Gastric Cancer
Trefoil Factor Interactions(Z 1
Cellular Localisation Secreted
Alternative CLIA Names Gastrokine-2 CLIA kit
Blottin CLIA kit
Down-Regulated In Gastric Cancer CLIA kit
Trefoil Factor Interactions(Z 1 CLIA kit
GKN2 CLIA kit
BLOT CLIA kit
GDDR CLIA kit
TFIZ1 CLIA kit
UNQ465 CLIA kit
PRO813 CLIA kit
Specificity This kit recognizes Human GKN2 in samples. No significant cross-reactivity or interference between Human GKN2 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 89-103 95
EDTA plasma(n=8) 98-115 106
Cell culture media(n=8) 99-115 107

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 43.39 111.17 368.00 42.61 112.61 357.61
Standard deviation 4.99 13.27 40.81 3.85 9.18 34.47
CV (%) 11.50 11.94 11.09 9.04 8.15 9.64
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance