• Human EXT1 (Exostosin-1) CLIA Kit (STJC0000627)

Human EXT1 (Exostosin-1) CLIA Kit (STJC0000627)

SKU:
STJC0000627

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.09ng/mL
Detection Limit: 0.16~10ng/mL
Short Description: This human EXT1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: EXT1
Gene ID: 2131
Uniprot ID: EXT1_HUMAN
Specificity: This kit recognizes Human EXT1 in samples. No significant cross-reactivity or interference between Human EXT1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Ubiquitous.
Function Glycosyltransferase required for the biosynthesis of heparan-sulfate. The EXT1/EXT2 complex possesses substantially higher glycosyltransferase activity than EXT1 or EXT2 alone. Appears to be a tumor suppressor. Required for the exosomal release of SDCBP, CD63 and syndecan.
Protein Name Exostosin-1
Glucuronosyl-N-Acetylglucosaminyl-Proteoglycan/N-Acetylglucosaminyl-Proteoglycan 4-Alpha-N-Acetylglucosaminyltransferase
Multiple Exostoses Protein 1
Putative Tumor Suppressor Protein Ext1
Database Links Reactome: R-HSA-2022928
Reactome: R-HSA-3656237
Reactome: R-HSA-3656253
Cellular Localisation Endoplasmic Reticulum Membrane
Single-Pass Type Ii Membrane Protein
Golgi Apparatus Membrane
Golgi Apparatus
Cis-Golgi Network Membrane
The Ext1/Ext2 Complex Is Localized In The Golgi Apparatus
Alternative CLIA Names Exostosin-1 CLIA kit
Glucuronosyl-N-Acetylglucosaminyl-Proteoglycan/N-Acetylglucosaminyl-Proteoglycan 4-Alpha-N-Acetylglucosaminyltransferase CLIA kit
Multiple Exostoses Protein 1 CLIA kit
Putative Tumor Suppressor Protein Ext1 CLIA kit
EXT1 CLIA kit
Specificity This kit recognizes Human EXT1 in samples. No significant cross-reactivity or interference between Human EXT1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 99-112 104
EDTA plasma(n=8) 96-106 101
Cell culture media(n=8) 96-110 101

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 0.53 1.42 4.28 0.49 1.38 4.10
Standard deviation 0.06 0.14 0.44 0.05 0.10 0.47
CV (%) 11.32 9.86 10.28 10.20 7.25 11.46
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance