Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.09ng/mL |
Detection Limit: |
0.16~10ng/mL |
Short Description: |
This human EXT1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
EXT1 |
Gene ID: |
2131 |
Uniprot ID: |
EXT1_HUMAN |
Specificity: |
This kit recognizes Human EXT1 in samples. No significant cross-reactivity or interference between Human EXT1 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Ubiquitous. |
Function | Glycosyltransferase required for the biosynthesis of heparan-sulfate. The EXT1/EXT2 complex possesses substantially higher glycosyltransferase activity than EXT1 or EXT2 alone. Appears to be a tumor suppressor. Required for the exosomal release of SDCBP, CD63 and syndecan. |
Protein Name | Exostosin-1Glucuronosyl-N-Acetylglucosaminyl-Proteoglycan/N-Acetylglucosaminyl-Proteoglycan 4-Alpha-N-AcetylglucosaminyltransferaseMultiple Exostoses Protein 1Putative Tumor Suppressor Protein Ext1 |
Database Links | Reactome: R-HSA-2022928Reactome: R-HSA-3656237Reactome: R-HSA-3656253 |
Cellular Localisation | Endoplasmic Reticulum MembraneSingle-Pass Type Ii Membrane ProteinGolgi Apparatus MembraneGolgi ApparatusCis-Golgi Network MembraneThe Ext1/Ext2 Complex Is Localized In The Golgi Apparatus |
Alternative CLIA Names | Exostosin-1 CLIA kitGlucuronosyl-N-Acetylglucosaminyl-Proteoglycan/N-Acetylglucosaminyl-Proteoglycan 4-Alpha-N-Acetylglucosaminyltransferase CLIA kitMultiple Exostoses Protein 1 CLIA kitPutative Tumor Suppressor Protein Ext1 CLIA kitEXT1 CLIA kit |
Specificity | This kit recognizes Human EXT1 in samples. No significant cross-reactivity or interference between Human EXT1 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 99-112 | 104 |
EDTA plasma(n=8) | 96-106 | 101 |
Cell culture media(n=8) | 96-110 | 101 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 0.53 | 1.42 | 4.28 | 0.49 | 1.38 | 4.10 |
Standard deviation | 0.06 | 0.14 | 0.44 | 0.05 | 0.10 | 0.47 |
CV (%) | 11.32 | 9.86 | 10.28 | 10.20 | 7.25 | 11.46 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance