• Human DNM1 (Dynamin-1) CLIA Kit (STJC0000568)

Human DNM1 (Dynamin-1) CLIA Kit (STJC0000568)

SKU:
STJC0000568

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 46.88pg/mL
Detection Limit: 78.13~5000pg/mL
Short Description: This human DNM1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: DNM1
Gene ID: 1759
Uniprot ID: DYN1_HUMAN
Specificity: This kit recognizes Human DNM1 in samples. No significant cross-reactivity or interference between Human DNM1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Microtubule-associated force-producing protein involved in producing microtubule bundles and able to bind and hydrolyze GTP. Most probably involved in vesicular trafficking processes. Involved in receptor-mediated endocytosis.
Protein Name Dynamin-1
Database Links Reactome: R-HSA-166016
Reactome: R-HSA-177504
Reactome: R-HSA-190873
Reactome: R-HSA-196025
Reactome: R-HSA-2132295
Reactome: R-HSA-3928665
Reactome: R-HSA-437239
Reactome: R-HSA-8856828
Cellular Localisation Cytoplasm
Cytoskeleton
Microtubule-Associated
Alternative CLIA Names Dynamin-1 CLIA kit
DNM1 CLIA kit
DNM CLIA kit
Specificity This kit recognizes Human DNM1 in samples. No significant cross-reactivity or interference between Human DNM1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 83-96 90
EDTA plasma(n=8) 97-113 104
Cell culture media(n=8) 100-113 106

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 233.59 449.68 2231.50 214.88 427.54 2234.09
Standard deviation 22.70 51.08 254.61 26.09 40.83 232.12
CV (%) 9.72 11.36 11.41 12.14 9.55 10.39
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance