• Human DBP (D site-binding protein) CLIA Kit (STJC0000728)

Human DBP (D site-binding protein) CLIA Kit (STJC0000728)

SKU:
STJC0000728

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.47ng/mL
Detection Limit: 0.78~50ng/mL
Short Description: This human DBP kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: DBP
Gene ID: 1628
Uniprot ID: DBP_HUMAN
Specificity: This kit recognizes Human DBP in samples. No significant cross-reactivity or interference between Human DBP and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Ubiquitously expressed. Expressed in the suprachiasmatic nuclei (SCN) and in most peripheral tissues, with a strong circadian rhythmicity.
Function This transcriptional activator recognizes and binds to the sequence 5'-RTTAYGTAAY-3' found in the promoter of genes such as albumin, CYP2A4 and CYP2A5. It is not essential for circadian rhythm generation, but modulates important clock output genes. May be a direct target for regulation by the circadian pacemaker component clock. May affect circadian period and sleep regulation.
Protein Name D Site-Binding Protein
Albumin D Box-Binding Protein
Albumin D-Element-Binding Protein
Tax-Responsive Enhancer Element-Binding Protein 302
Taxreb302
Database Links Reactome: R-HSA-1368108
Cellular Localisation Nucleus
Alternative CLIA Names D Site-Binding Protein CLIA kit
Albumin D Box-Binding Protein CLIA kit
Albumin D-Element-Binding Protein CLIA kit
Tax-Responsive Enhancer Element-Binding Protein 302 CLIA kit
Taxreb302 CLIA kit
DBP CLIA kit
Specificity This kit recognizes Human DBP in samples. No significant cross-reactivity or interference between Human DBP and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 88-103 95
EDTA plasma(n=8) 100-115 107
Cell culture media(n=8) 96-114 104

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 2.68 6.65 21.26 2.46 6.47 23.06
Standard deviation 0.35 0.56 1.71 0.30 0.52 2.38
CV (%) 13.06 8.42 8.04 12.20 8.04 10.32
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance