• Human CXCL16 (C-X-C motif chemokine 16) CLIA Kit (STJC0000049)

Human CXCL16 (C-X-C motif chemokine 16) CLIA Kit (STJC0000049)

SKU:
STJC0000049

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human CXCL16 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CXCL16
Gene ID: 58191
Uniprot ID: CXL16_HUMAN
Specificity: This kit recognizes Human CXCL16 in samples. No significant cross-reactivity or interference between Human CXCL16 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed in T-cell areas. Expressed in spleen, lymph nodes, lung, kidney, small intestine and thymus. Weak expression in heart and liver and no expression in brain and bone marrow.
Post Translational Modifications Glycosylated.
Function Acts as a scavenger receptor on macrophages, which specifically binds to OxLDL (oxidized low density lipoprotein), suggesting that it may be involved in pathophysiology such as atherogenesis. Induces a strong chemotactic response. Induces calcium mobilization. Binds to CXCR6/Bonzo.
Protein Name C-X-C Motif Chemokine 16
Scavenger Receptor For Phosphatidylserine And Oxidized Low Density Lipoprotein
Sr-Psox
Small-Inducible Cytokine B16
Transmembrane Chemokine Cxcl16
Database Links Reactome: R-HSA-380108
Reactome: R-HSA-418594
Cellular Localisation Cell Membrane
Single-Pass Type I Membrane Protein
Secreted
Also Exists As A Soluble Form
Alternative CLIA Names C-X-C Motif Chemokine 16 CLIA kit
Scavenger Receptor For Phosphatidylserine And Oxidized Low Density Lipoprotein CLIA kit
Sr-Psox CLIA kit
Small-Inducible Cytokine B16 CLIA kit
Transmembrane Chemokine Cxcl16 CLIA kit
CXCL16 CLIA kit
SCYB16 CLIA kit
SRPSOX CLIA kit
UNQ2759 CLIA kit
PRO6714 CLIA kit
Specificity This kit recognizes Human CXCL16 in samples. No significant cross-reactivity or interference between Human CXCL16 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 100-117 107
EDTA plasma(n=8) 86-98 93
Cell culture media(n=8) 99-113 106

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 103.10 241.10 860.18 95.01 241.48 790.84
Standard deviation 11.45 17.72 81.72 12.08 22.51 90.63
CV (%) 11.11 7.35 9.50 12.71 9.32 11.46
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance