• Human CLDN9 (Claudin-9) CLIA Kit (STJC0000414)

Human CLDN9 (Claudin-9) CLIA Kit (STJC0000414)

SKU:
STJC0000414

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This human CLDN9 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CLDN9
Gene ID: 9080
Uniprot ID: CLD9_HUMAN
Specificity: This kit recognizes Human CLDN9 in samples. No significant cross-reactivity or interference between Human CLDN9 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed in the liver, in peripheral blood mononuclear cells and hepatocarcinoma cell lines.
Function Plays a major role in tight junction-specific obliteration of the intercellular space, through calcium-independent cell-adhesion activity. (Microbial infection) Acts as a receptor for hepatitis C virus (HCV) entry into hepatic cells.
Protein Name Claudin-9
Database Links Reactome: R-HSA-420029
Cellular Localisation Cell Junction
Tight Junction
Cell Membrane
Multi-Pass Membrane Protein
Alternative CLIA Names Claudin-9 CLIA kit
CLDN9 CLIA kit
Specificity This kit recognizes Human CLDN9 in samples. No significant cross-reactivity or interference between Human CLDN9 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-104 99
EDTA plasma(n=8) 87-98 93
Cell culture media(n=8) 89-101 96

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 54.38 104.94 446.34 53.69 111.81 407.67
Standard deviation 7.00 9.65 44.05 4.88 8.02 39.67
CV (%) 12.87 9.20 9.87 9.09 7.17 9.73
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance