• Human CFD (Complement factor D) CLIA Kit (STJC0000037)

Human CFD (Complement factor D) CLIA Kit (STJC0000037)

SKU:
STJC0000037

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 46.88pg/mL
Detection Limit: 78.13~5000pg/mL
Short Description: This human CFD kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CFD
Gene ID: 1675
Uniprot ID: CFAD_HUMAN
Specificity: This kit recognizes Human CFD in samples. No significant cross-reactivity or interference between Human CFD and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Factor D cleaves factor B when the latter is complexed with factor C3b, activating the C3bbb complex, which then becomes the C3 convertase of the alternate pathway. Its function is homologous to that of C1s in the classical pathway.
Protein Name Complement Factor D
Adipsin
C3 Convertase Activator
Properdin Factor D
Database Links Reactome: R-HSA-114608
Reactome: R-HSA-173736
Reactome: R-HSA-6798695
Cellular Localisation Secreted
Alternative CLIA Names Complement Factor D CLIA kit
Adipsin CLIA kit
C3 Convertase Activator CLIA kit
Properdin Factor D CLIA kit
CFD CLIA kit
DF CLIA kit
PFD CLIA kit
Specificity This kit recognizes Human CFD in samples. No significant cross-reactivity or interference between Human CFD and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 96-111 103
EDTA plasma(n=8) 84-95 90
Cell culture media(n=8) 100-116 107

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 233.24 687.31 2486.95 242.57 721.32 2632.72
Standard deviation 22.39 49.56 250.68 31.39 85.19 235.89
CV (%) 9.60 7.21 10.08 12.94 11.81 8.96
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance