Human CD30 (Cluster of Differentiation 30) Sandwich ELISA (STJE0019882)

SKU:
STJE0019882

Shipping:
Free Shipping
Current Stock:
Applications: ELISA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 13.01 pg/mL
Detection Limit: 31.25-2000 pg/mL
Short Description: This CD30 Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in human cell culture supernatant, serum and plasma (EDTA, citrate, heparin).
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Colormetric
Gene Symbol: TNFRSF8
Gene ID: 943
Uniprot ID: TNR8_HUMAN
Specificity: This kit recognizes Human CD30 in samples. No significant cross-reactivity or interference between Human CD30 and analogues was observed.
Sample Type: serum, plasma and other biological fluids
Tissue Specificity Isoform 2: Detected in alveolar macrophages (at protein level).
Post Translational Modifications Phosphorylated on serine and tyrosine residues (Probable). Isoform 2 is constitutively phosphorylated.
Function Receptor for TNFSF8/CD30L. May play a role in the regulation of cellular growth and transformation of activated lymphoblasts. Regulates gene expression through activation of NF-kappa-B.
Protein Name Tumor Necrosis Factor Receptor Superfamily Member 8
Cd30l Receptor
Ki-1 Antigen
Lymphocyte Activation Antigen Cd30
Cd Antigen Cd30
Database Links Reactome: R-HSA-5669034
Cellular Localisation Isoform 1: Cell Membrane
Single-Pass Type I Membrane Protein
Isoform 2: Cytoplasm
Alternative ELISA Names Tumor Necrosis Factor Receptor Superfamily Member 8 ELISA kit
Cd30l Receptor ELISA kit
Ki-1 Antigen ELISA kit
Lymphocyte Activation Antigen Cd30 ELISA kit
Cd Antigen Cd30 ELISA kit
TNFRSF8 ELISA kit
CD30 ELISA kit
D1S166E ELISA kit
Specificity This kit recognizes Human CD30 in samples. No significant cross-reactivity or interference between Human CD30 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro ELISA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent 1 vial, 10 mL 2-8℃ (Protect from light)
Stop Solution 1 vial, 10 mL 2-8°C
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 90-106 97
EDTA plasma (n=8) 90-102 96
Cell culture media (n=8) 86-101 93

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 108.79 212.31 695.95 117.56 225.86 706.57
Standard deviation 5.66 11.85 21.23 6.65 11.84 38.72
CV (%) 5.20 5.58 3.05 5.66 5.24 5.48
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance