Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
4.69pg/mL |
Detection Limit: |
7.81~500pg/mL |
Short Description: |
This human CCL19 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
CCL19 |
Gene ID: |
6363 |
Uniprot ID: |
CCL19_HUMAN |
Specificity: |
This kit recognizes Human MIP-3 Beta/ELC/CCL19 in samples. No significant cross-reactivity or interference between Human MIP-3 Beta/ELC/CCL19 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Expressed at high levels in the lymph nodes, thymus and appendix. Intermediate levels seen in colon and trachea, while low levels found in spleen, small intestine, lung, kidney and stomach. |
Function | May play a role not only in inflammatory and immunological responses but also in normal lymphocyte recirculation and homing. May play an important role in trafficking of T-cells in thymus, and T-cell and B-cell migration to secondary lymphoid organs. Binds to chemokine receptor CCR7. Recombinant CCL19 shows potent chemotactic activity for T-cells and B-cells but not for granulocytes and monocytes. Binds to atypical chemokine receptor ACKR4 and mediates the recruitment of beta-arrestin (ARRB1/2) to ACKR4. |
Protein Name | C-C Motif Chemokine 19Beta-Chemokine Exodus-3Ck Beta-11Epstein-Barr Virus-Induced Molecule 1 Ligand ChemokineEbi1 Ligand ChemokineElcMacrophage Inflammatory Protein 3 BetaMip-3-BetaSmall-Inducible Cytokine A19 |
Database Links | Reactome: R-HSA-380108Reactome: R-HSA-418594Reactome: R-HSA-6783783 |
Cellular Localisation | Secreted |
Alternative CLIA Names | C-C Motif Chemokine 19 CLIA kitBeta-Chemokine Exodus-3 CLIA kitCk Beta-11 CLIA kitEpstein-Barr Virus-Induced Molecule 1 Ligand Chemokine CLIA kitEbi1 Ligand Chemokine CLIA kitElc CLIA kitMacrophage Inflammatory Protein 3 Beta CLIA kitMip-3-Beta CLIA kitSmall-Inducible Cytokine A19 CLIA kitCCL19 CLIA kitELC CLIA kitMIP3B CLIA kitSCYA19 CLIA kit |
Specificity | This kit recognizes Human MIP-3β/ELC/CCL19 in samples. No significant cross-reactivity or interference between Human MIP-3β/ELC/CCL19 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 93-110 | 101 |
EDTA plasma(n=8) | 94-107 | 101 |
Cell culture media(n=8) | 86-96 | 91 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 24.66 | 74.00 | 201.06 | 24.25 | 69.15 | 217.53 |
Standard deviation | 3.00 | 6.76 | 18.82 | 2.32 | 5.38 | 21.82 |
CV (%) | 12.17 | 9.14 | 9.36 | 9.57 | 7.78 | 10.03 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance