Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
18.75pg/mL |
Detection Limit: |
31.25~2000pg/mL |
Short Description: |
This human APOF kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
APOF |
Gene ID: |
319 |
Uniprot ID: |
APOF_HUMAN |
Specificity: |
This kit recognizes Human ApoF in samples. No significant cross-reactivity or interference between Human ApoF and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Expressed by the liver and secreted in plasma. |
Post Translational Modifications | O-glycosylated with core 1 or possibly core 8 glycans. |
Function | Minor apolipoprotein that associates with LDL. Inhibits cholesteryl ester transfer protein (CETP) activity and appears to be an important regulator of cholesterol transport. Also associates to a lesser degree with VLDL, Apo-AI and Apo-AII. |
Protein Name | Apolipoprotein FApo-FLipid Transfer Inhibitor ProteinLtip |
Database Links | Reactome: R-HSA-8964041 |
Cellular Localisation | Secreted |
Alternative CLIA Names | Apolipoprotein F CLIA kitApo-F CLIA kitLipid Transfer Inhibitor Protein CLIA kitLtip CLIA kitAPOF CLIA kit |
Specificity | This kit recognizes Human ApoF in samples. No significant cross-reactivity or interference between Human ApoF and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 87-99 | 92 |
EDTA plasma(n=8) | 90-102 | 95 |
Cell culture media(n=8) | 85-101 | 92 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 99.93 | 230.64 | 749.83 | 100.77 | 218.82 | 783.73 |
Standard deviation | 10.16 | 16.17 | 71.98 | 8.22 | 22.12 | 63.01 |
CV (%) | 10.17 | 7.01 | 9.60 | 8.16 | 10.11 | 8.04 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance