• Human APOF (Apolipoprotein F) CLIA Kit (STJC0000277)

Human APOF (Apolipoprotein F) CLIA Kit (STJC0000277)

SKU:
STJC0000277

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human APOF kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: APOF
Gene ID: 319
Uniprot ID: APOF_HUMAN
Specificity: This kit recognizes Human ApoF in samples. No significant cross-reactivity or interference between Human ApoF and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed by the liver and secreted in plasma.
Post Translational Modifications O-glycosylated with core 1 or possibly core 8 glycans.
Function Minor apolipoprotein that associates with LDL. Inhibits cholesteryl ester transfer protein (CETP) activity and appears to be an important regulator of cholesterol transport. Also associates to a lesser degree with VLDL, Apo-AI and Apo-AII.
Protein Name Apolipoprotein F
Apo-F
Lipid Transfer Inhibitor Protein
Ltip
Database Links Reactome: R-HSA-8964041
Cellular Localisation Secreted
Alternative CLIA Names Apolipoprotein F CLIA kit
Apo-F CLIA kit
Lipid Transfer Inhibitor Protein CLIA kit
Ltip CLIA kit
APOF CLIA kit
Specificity This kit recognizes Human ApoF in samples. No significant cross-reactivity or interference between Human ApoF and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 87-99 92
EDTA plasma(n=8) 90-102 95
Cell culture media(n=8) 85-101 92

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 99.93 230.64 749.83 100.77 218.82 783.73
Standard deviation 10.16 16.17 71.98 8.22 22.12 63.01
CV (%) 10.17 7.01 9.60 8.16 10.11 8.04
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance