• Human APOC4 (Apolipoprotein C-IV) CLIA Kit (STJC0000274)

Human APOC4 (Apolipoprotein C-IV) CLIA Kit (STJC0000274)

SKU:
STJC0000274

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 4.69pg/mL
Detection Limit: 7.81~500pg/mL
Short Description: This human APOC4 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: APOC4
Gene ID: 346
Uniprot ID: APOC4_HUMAN
Specificity: This kit recognizes Human ApoC4 in samples. No significant cross-reactivity or interference between Human ApoC4 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed by the liver and secreted in plasma.
Function May participate in lipoprotein metabolism.
Protein Name Apolipoprotein C-Iv
Apo-Civ
Apoc-Iv
Apolipoprotein C4
Database Links Reactome: R-HSA-8866423
Reactome: R-HSA-8964046
Reactome: R-HSA-9029569
Cellular Localisation Secreted
Alternative CLIA Names Apolipoprotein C-Iv CLIA kit
Apo-Civ CLIA kit
Apoc-Iv CLIA kit
Apolipoprotein C4 CLIA kit
APOC4 CLIA kit
Specificity This kit recognizes Human ApoC4 in samples. No significant cross-reactivity or interference between Human ApoC4 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 94-111 101
EDTA plasma(n=8) 97-110 103
Cell culture media(n=8) 98-116 106

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 25.28 58.53 193.77 24.87 56.91 197.83
Standard deviation 2.82 6.46 11.66 2.18 4.23 21.19
CV (%) 11.16 11.04 6.02 8.77 7.43 10.71
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance