Human AOC3 (Membrane primary amine oxidase) Sandwich ELISA (STJE0003568)

SKU:
STJE0003568

Shipping:
Free Shipping
Current Stock:
Applications: ELISA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This AOC3 Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in human cell culture supernatant, serum and plasma (EDTA, citrate, heparin).
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Colormetric
Gene Symbol: AOC3
Gene ID: 8639
Uniprot ID: AOC3_HUMAN
Specificity: This kit recognizes Human VAP-1 in samples. No significant cross-reactivity or interference between Human VAP-1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications Topaquinone (TPQ) is generated by copper-dependent autoxidation of a specific tyrosyl residue. N- and O-glycosylated.
Function Cell adhesion protein that participates in lymphocyte extravasation and recirculation by mediating the binding of lymphocytes to peripheral lymph node vascular endothelial cells in an L-selectin-independent fashion. Has semicarbazide-sensitive (SSAO) monoamine oxidase activity. May play a role in adipogenesis.
Protein Name Membrane Primary Amine Oxidase
Copper Amine Oxidase
Hpao
Semicarbazide-Sensitive Amine Oxidase
Ssao
Vascular Adhesion Protein 1
Vap-1
Database Links Reactome: R-HSA-211945
Cellular Localisation Cell Membrane
Single-Pass Type Ii Membrane Protein
Alternative ELISA Names Membrane Primary Amine Oxidase ELISA kit
Copper Amine Oxidase ELISA kit
Hpao ELISA kit
Semicarbazide-Sensitive Amine Oxidase ELISA kit
Ssao ELISA kit
Vascular Adhesion Protein 1 ELISA kit
Vap-1 ELISA kit
AOC3 ELISA kit
VAP1 ELISA kit
Specificity This kit recognizes Human VAP-1 in samples. No significant cross-reactivity or interference between Human VAP-1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro ELISA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent 1 vial, 10 mL 2-8℃ (Protect from light)
Stop Solution 1 vial, 10 mL 2-8°C
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 92-110 100
EDTA plasma (n=8) 87-98 92
Cell culture media (n=8) 83-96 90

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 102.88 240.69 685.30 104.85 253.32 743.12
Standard deviation 5.62 11.02 25.77 5.33 14.69 39.39
CV (%) 5.46 4.58 3.76 5.08 5.80 5.30
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance