Human ANGPTL1 (Angiopoietin-related protein 1) CLIA Kit (STJC0000201)

SKU:
STJC0000201

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human ANGPTL1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: ANGPTL1
Gene ID: 9068
Uniprot ID: ANGL1_HUMAN
Specificity: This kit recognizes Human ANGPTL1 in samples. No significant cross-reactivity or interference between Human ANGPTL1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Highly expressed in adrenal gland, placenta, thyroid gland, heart, skeletal muscle and small intestine. Weakly expressed in testis, ovary, colon, pancreas, kidney and stomach.
Protein Name Angiopoietin-Related Protein 1
Angiopoietin-3
Ang-3
Angiopoietin-Like Protein 1
Cellular Localisation Secreted
Alternative CLIA Names Angiopoietin-Related Protein 1 CLIA kit
Angiopoietin-3 CLIA kit
Ang-3 CLIA kit
Angiopoietin-Like Protein 1 CLIA kit
ANGPTL1 CLIA kit
ANG3 CLIA kit
ANGPT3 CLIA kit
ARP1 CLIA kit
PSEC0154 CLIA kit
UNQ162 CLIA kit
PRO188 CLIA kit
Specificity This kit recognizes Human ANGPTL1 in samples. No significant cross-reactivity or interference between Human ANGPTL1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 91-104 96
EDTA plasma(n=8) 89-104 96
Cell culture media(n=8) 88-102 93

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 102.95 178.13 992.75 111.18 176.64 1033.93
Standard deviation 10.46 17.78 75.75 12.39 17.89 117.45
CV (%) 10.16 9.98 7.63 11.14 10.13 11.36
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance