Applications: |
ELISA |
Reactivity: |
Rat |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.19ng/mL |
Detection Limit: |
0.31~20ng/mL |
Short Description: |
This Mmp2 Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in rat cell culture supernatant, serum and plasma (EDTA, citrate, heparin). |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Colormetric |
Gene Symbol: |
Mmp2 |
Gene ID: |
81686 |
Uniprot ID: |
MMP2_RAT |
Specificity: |
This kit recognizes Rat MMP-2 in samples. No significant cross-reactivity or interference between Rat MMP-2 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Function | Ubiquitinous metalloproteinase that is involved in diverse functions such as remodeling of the vasculature, angiogenesis, tissue repair, tumor invasion, inflammation, and atherosclerotic plaque rupture. As well as degrading extracellular matrix proteins, can also act on several nonmatrix proteins such as big endothelial 1 and beta-type CGRP promoting vasoconstriction. Also cleaves KISS at a Gly-|-Leu bond. Appears to have a role in myocardial cell death pathways. Contributes to myocardial oxidative stress by regulating the activity of GSK3beta. Cleaves GSK3beta in vitro. Involved in the formation of the fibrovascular tissues. PEX, the C-terminal non-catalytic fragment of MMP2, posseses anti-angiogenic and anti-tumor properties and inhibits cell migration and cell adhesion to FGF2 and vitronectin. Ligand for integrin alpha-v/beta3 on the surface of blood vessels. |
Protein Name | 72 Kda Type Iv Collagenase72 Kda GelatinaseGelatinase AMatrix Metalloproteinase-2Mmp-2 Cleaved Into - Pex |
Database Links | Reactome: R-RNO-1442490Reactome: -RNO-1474228Reactome: -RNO-1592389Reactome: -RNO-381426Reactome: -RNO-3928665Reactome: -RNO-9009391 |
Cellular Localisation | SecretedExtracellular SpaceExtracellular MatrixMembraneNucleusColocalizes With Integrin Alphav/Beta3 At The Membrane Surface In Angiogenic Blood Vessels And MelanomasFound In MitochondriaAlong MicrofibrilsAnd In Nuclei Of Cardiomyocytes |
Alternative ELISA Names | 72 Kda Type Iv Collagenase ELISA kit72 Kda Gelatinase ELISA kitGelatinase A ELISA kitMatrix Metalloproteinase-2 ELISA kitMmp-2 Cleaved Into - Pex ELISA kitMmp2 ELISA kit |
Specificity | This kit recognizes Rat MMP-2 in samples. No significant cross-reactivity or interference between Rat MMP-2 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent | 1 vial, 10 mL | 2-8℃ (Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 88-100 | 93 |
EDTA plasma (n=8) | 89-103 | 96 |
Cell culture media (n=8) | 86-96 | 91 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 1.10 | 3.00 | 8.70 | 1.10 | 3.20 | 9.30 |
Standard deviation | 0.10 | 0.20 | 0.40 | 0.10 | 0.20 | 0.40 |
CV (%) | 9.09 | 6.67 | 4.60 | 9.09 | 6.25 | 4.30 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance