• Rat Mmp12 (Macrophage metalloelastase) Sandwich ELISA (STJE0005454)

Rat Mmp12 (Macrophage metalloelastase) Sandwich ELISA (STJE0005454)

SKU:
STJE0005454

Shipping:
Free Shipping
Current Stock:
Applications: ELISA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 46.88pg/mL
Detection Limit: 78.13~5000pg/mL
Short Description: This Mmp12 Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in rat cell culture supernatant, serum and plasma (EDTA, citrate, heparin).
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Colormetric
Gene Symbol: Mmp12
Gene ID: 117033
Uniprot ID: MMP12_RAT
Specificity: This kit recognizes Rat MMP-12 in samples. No significant cross-reactivity or interference between Rat MMP-12 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Protein Name Macrophage Metalloelastase
Mme
Matrix Metalloproteinase-12
Mmp-12
Database Links Reactome: R-RNO-1442490
Reactome: -RNO-1474228
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Alternative ELISA Names Macrophage Metalloelastase ELISA kit
Mme ELISA kit
Matrix Metalloproteinase-12 ELISA kit
Mmp-12 ELISA kit
Mmp12 ELISA kit
Mmel ELISA kit
Specificity This kit recognizes Rat MMP-12 in samples. No significant cross-reactivity or interference between Rat MMP-12 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro ELISA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent 1 vial, 10 mL 2-8℃ (Protect from light)
Stop Solution 1 vial, 10 mL 2-8°C
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 90-103 97
EDTA plasma (n=8) 95-110 102
Cell culture media (n=8) 91-106 98

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 246.17 699.83 1945.51 236.26 762.26 2004.72
Standard deviation 14.94 32.82 97.08 13.25 44.59 63.75
CV (%) 6.07 4.69 4.99 5.61 5.85 3.18
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance