• Rat MHC2/AgB2/H-12 (Major Histocompatibility Complex-2) CLIA Kit (STJC0001794)

Rat MHC2/AgB2/H-12 (Major Histocompatibility Complex-2) CLIA Kit (STJC0001794)

SKU:
STJC0001794

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.94ng/mL
Detection Limit: 1.56~100ng/mL
Short Description: This rat MHC2/AgB2/H-12 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Specificity: This kit recognizes Rat MHC 2/AgB 2/H-1 2 in samples. No significant cross-reactivity or interference between Rat MHC 2/AgB 2/H-1 2 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Specificity This kit recognizes Rat MHCⅡ/AgBⅡ/H-1Ⅱ in samples. No significant cross-reactivity or interference between Rat MHCⅡ/AgBⅡ/H-1Ⅱ and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 95-109 102
EDTA plasma(n=8) 88-102 93
Cell culture media(n=8) 87-98 92

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 4.60 9.24 48.23 5.03 8.78 50.51
Standard deviation 0.54 1.02 3.57 0.62 0.96 5.16
CV (%) 11.74 11.04 7.40 12.33 10.93 10.22
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance