• Rat Lptn/XCL1 (Lymphotactin) CLIA Kit (STJC0001787)

Rat Lptn/XCL1 (Lymphotactin) CLIA Kit (STJC0001787)

SKU:
STJC0001787

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This rat Lptn/XCL1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Xcl1
Gene ID: 171371
Uniprot ID: XCL1_RAT
Specificity: This kit recognizes Rat Lptn/XCL1 in samples. No significant cross-reactivity or interference between Rat Lptn/XCL1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Chemotactic activity for lymphocytes but not for monocytes or neutrophils. In thymus, mediates medullary accumulation of thymic dendritic cells and contributes to regulatoy T cell development, playing a role in self-tolerance establishment.
Protein Name Lymphotactin
C Motif Chemokine 1
Cytokine Scm-1
Small-Inducible Cytokine C1
Database Links Reactome: R-RNO-380108
Reactome: -RNO-416476
Cellular Localisation Secreted
Alternative CLIA Names Lymphotactin CLIA kit
C Motif Chemokine 1 CLIA kit
Cytokine Scm-1 CLIA kit
Small-Inducible Cytokine C1 CLIA kit
Xcl1 CLIA kit
Ltn CLIA kit
Scyc1 CLIA kit
Specificity This kit recognizes Rat Lptn/XCL1 in samples. No significant cross-reactivity or interference between Rat Lptn/XCL1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 94-110 100
EDTA plasma(n=8) 91-105 98
Cell culture media(n=8) 88-102 95

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 53.55 95.96 470.23 54.40 88.29 455.56
Standard deviation 5.68 8.57 32.59 5.85 6.97 30.07
CV (%) 10.61 8.93 6.93 10.75 7.89 6.60
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance