• Rat LIFR (Leukemia Inhibitory Factor Receptor) CLIA Kit (STJC0001781)

Rat LIFR (Leukemia Inhibitory Factor Receptor) CLIA Kit (STJC0001781)

SKU:
STJC0001781

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This rat LIFR kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Lifr
Gene ID: 81680
Uniprot ID: LIFR_RAT
Specificity: This kit recognizes Rat LIFR in samples. No significant cross-reactivity or interference between Rat LIFR and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Signal-transducing molecule. May have a common pathway with IL6ST. The soluble form inhibits the biological activity of LIF by blocking its binding to receptors on target cells.
Protein Name Leukemia Inhibitory Factor Receptor
Lif Receptor
Lif-R
Cd Antigen Cd118
Database Links Reactome: R-RNO-6788467
Cellular Localisation Cell Membrane
Single-Pass Type I Membrane Protein
Alternative CLIA Names Leukemia Inhibitory Factor Receptor CLIA kit
Lif Receptor CLIA kit
Lif-R CLIA kit
Cd Antigen Cd118 CLIA kit
Lifr CLIA kit
Specificity This kit recognizes Rat LIFR in samples. No significant cross-reactivity or interference between Rat LIFR and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 97-112 102
EDTA plasma(n=8) 97-109 104
Cell culture media(n=8) 90-102 96

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 202.39 415.89 1861.79 184.30 430.63 1799.94
Standard deviation 26.01 43.29 163.09 22.06 43.28 119.16
CV (%) 12.85 10.41 8.76 11.97 10.05 6.62
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance