• Rat FABP3 (Fatty Acid Binding Protein 3, Muscle and Heart) CLIA Kit (STJC0001876)

Rat FABP3 (Fatty Acid Binding Protein 3, Muscle and Heart) CLIA Kit (STJC0001876)

SKU:
STJC0001876

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This rat FABP3 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Fabp3
Gene ID: 79131
Uniprot ID: FABPH_RAT
Specificity: This kit recognizes Rat FABP3 in samples. No significant cross-reactivity or interference between Rat FABP3 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Heart, but also skeletal muscle, kidney, brain and mammary gland.
Function FABPs are thought to play a role in the intracellular transport of long-chain fatty acids and their acyl-CoA esters.
Protein Name Fatty Acid-Binding Protein - Heart
Fatty Acid-Binding Protein 3
Heart-Type Fatty Acid-Binding Protein
H-Fabp
Database Links Reactome: R-RNO-163560
Cellular Localisation Cytoplasm
Alternative CLIA Names Fatty Acid-Binding Protein - Heart CLIA kit
Fatty Acid-Binding Protein 3 CLIA kit
Heart-Type Fatty Acid-Binding Protein CLIA kit
H-Fabp CLIA kit
Fabp3 CLIA kit
Specificity This kit recognizes Rat FABP3 in samples. No significant cross-reactivity or interference between Rat FABP3 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 90-103 95
EDTA plasma(n=8) 84-98 91
Cell culture media(n=8) 86-97 91

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 91.61 261.81 888.57 89.03 238.87 943.11
Standard deviation 10.27 20.76 66.29 7.51 17.39 97.52
CV (%) 11.21 7.93 7.46 8.44 7.28 10.34
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance