• Rat CXCL5 (Chemokine C-X-C-Motif Ligand 5) CLIA Kit (STJC0001669)

Rat CXCL5 (Chemokine C-X-C-Motif Ligand 5) CLIA Kit (STJC0001669)

SKU:
STJC0001669

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 4.69pg/mL
Detection Limit: 7.81~500pg/mL
Short Description: This rat CXCL5 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Cxcl5
Gene ID: 60665
Uniprot ID: CXCL5_RAT
Specificity: This kit recognizes Rat CXCL5 in samples. No significant cross-reactivity or interference between Rat CXCL5 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function May participate in the recruitment of inflammatory cells by injured or infected tissue.
Protein Name C-X-C Motif Chemokine 5
Cytokine Lix
Small-Inducible Cytokine B5
Database Links Reactome: R-RNO-380108
Reactome: -RNO-418594
Cellular Localisation Secreted
Alternative CLIA Names C-X-C Motif Chemokine 5 CLIA kit
Cytokine Lix CLIA kit
Small-Inducible Cytokine B5 CLIA kit
Cxcl5 CLIA kit
Scyb5 CLIA kit
Specificity This kit recognizes Rat CXCL5 in samples. No significant cross-reactivity or interference between Rat CXCL5 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 94-108 102
EDTA plasma(n=8) 92-106 98
Cell culture media(n=8) 99-114 105

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 26.42 66.24 204.74 27.44 62.76 207.92
Standard deviation 2.89 5.80 22.79 3.28 7.20 21.33
CV (%) 10.94 8.76 11.13 11.95 11.47 10.26
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance