• Rat Comp (Cartilage oligomeric matrix protein) Sandwich ELISA (STJE0005537)
  • Rat Comp (Cartilage oligomeric matrix protein) Sandwich ELISA (STJE0005537)

Rat Comp (Cartilage oligomeric matrix protein) Sandwich ELISA (STJE0005537)

SKU:
STJE0005537

Shipping:
Free Shipping
Current Stock:
Applications: ELISA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.94ng/mL
Detection Limit: 1.56~100ng/mL
Short Description: This Comp Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in rat cell culture supernatant, serum and plasma (EDTA, citrate, heparin).
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Colormetric
Gene Symbol: Comp
Gene ID: 25304
Uniprot ID: COMP_RAT
Specificity: This kit recognizes Rat COMP in samples. No significant cross-reactivity or interference between Rat COMP and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Protein Name Cartilage Oligomeric Matrix Protein
Comp
Database Links Reactome: R-RNO-216083
Reactome: -RNO-3000178
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Alternative ELISA Names Cartilage Oligomeric Matrix Protein ELISA kit
Comp ELISA kit
Comp ELISA kit
Specificity This kit recognizes Rat COMP in samples. No significant cross-reactivity or interference between Rat COMP and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro ELISA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent 1 vial, 10 mL 2-8℃ (Protect from light)
Stop Solution 1 vial, 10 mL 2-8°C
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 95-107 101
EDTA plasma (n=8) 93-107 99
Cell culture media (n=8) 88-99 93

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 5.25 10.89 43.87 5.28 10.04 39.84
Standard deviation 0.36 0.52 1.41 0.27 0.47 1.33
CV (%) 6.86 4.78 3.21 5.11 4.68 3.34
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance