• Rat CCKAR (Cholecystokinin A Receptor) CLIA Kit (STJC0001601)

Rat CCKAR (Cholecystokinin A Receptor) CLIA Kit (STJC0001601)

SKU:
STJC0001601

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This rat CCKAR kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Cckar
Gene ID: 24889
Uniprot ID: CCKAR_RAT
Specificity: This kit recognizes Rat CCKAR in samples. No significant cross-reactivity or interference between Rat CCKAR and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Pancreas and brain. Also expressed in the gastrointestinal system and vagus nerve.
Function Receptor for cholecystokinin. Mediates pancreatic growth and enzyme secretion, smooth muscle contraction of the gall bladder and stomach. Has a 1000-fold higher affinity for CCK rather than for gastrin. It modulates feeding and dopamine-induced behavior in the central and peripheral nervous system. This receptor mediates its action by association with G proteins that activate a phosphatidylinositol-calcium second messenger system.
Protein Name Cholecystokinin Receptor Type A
Cck-A Receptor
Cck-Ar
Cholecystokinin-1 Receptor
Cck1-R
Database Links Reactome: R-RNO-375276
Reactome: -RNO-416476
Cellular Localisation Cell Membrane
Multi-Pass Membrane Protein
Alternative CLIA Names Cholecystokinin Receptor Type A CLIA kit
Cck-A Receptor CLIA kit
Cck-Ar CLIA kit
Cholecystokinin-1 Receptor CLIA kit
Cck1-R CLIA kit
Cckar CLIA kit
Specificity This kit recognizes Rat CCKAR in samples. No significant cross-reactivity or interference between Rat CCKAR and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 98-110 104
EDTA plasma(n=8) 97-110 103
Cell culture media(n=8) 94-106 100

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 92.19 226.96 829.93 90.35 218.98 791.15
Standard deviation 9.70 16.66 79.18 11.18 17.01 56.57
CV (%) 10.52 7.34 9.54 12.37 7.77 7.15
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance