Applications: |
ELISA |
Reactivity: |
Mouse |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.19ng/mL |
Detection Limit: |
0.31~20ng/mL |
Short Description: |
This IgG2c Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in mouse cell culture supernatant, serum and plasma (EDTA, citrate, heparin). |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 6 months. Following first use any unused wells and reagents should be stored according to the components table in the manual. |
Assay Time: |
1.5h |
Detection: |
Colormetric |
Specificity: |
This kit recognizes Mouse IgG2c in samples. No significant cross-reactivity or interference between Mouse IgG2c and analogues was observed. |
Sample Type: |
serum, plasma and other biological fluids |
Specificity | This kit recognizes IgG2c in samples. No significant cross-reactivity or interference between IgG2c and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips 24T: 8 wells ×3 strips 96T*5: 5 plates, 96T | 2-8℃, 1 months |
Reference Standard | 96T: 2 vials 48T/24T: 1 vial 96T*5: 10 vials | 2-8℃, use the reconstituted standard within 24h |
Concentrated HRP Linked Detection Ab (100×) | 96T: 1 vial, 60 μL 48T/24T: 1 vial, 30 μL 96T*5: 5 vials, 60 μL | 2-8℃ (Protect from light) |
Reference Standard & Sample Diluent | 96T/48T/24T: 1 vial, 20 mL96T*5: 5 vials, 20 mL | 2-8℃ |
HRP Linked Ab Diluent | 96T/48T/24T: 1 vial, 14 mL96T*5: 5 vials, 14 mL | |
Concentrated Wash Buffer (25×) | 96T/48T/24T: 1 vial, 30 mL96T*5: 5 vials, 30 mL | |
Substrate Reagent | 96T/48T/24T: 1 vial, 10 mL96T*5: 5 vials, 10 mL | 2-8℃ (Protect from light) |
Stop Solution | 96T/48T/24T: 1 vial, 10 mL96T*5: 5 vials, 10 mL | 2-8℃ |
Plate Sealer | 96T/48T/24T: 5 pieces96T*5: 25 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 88-104 | 95 |
EDTA plasma(n=8) | 96-110 | 101 |
Cell culture media(n=8) | 90-103 | 96 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 1.05 | 2.51 | 8.22 | 1.03 | 2.53 | 8.52 |
Standard deviation | 0.06 | 0.12 | 0.36 | 0.07 | 0.13 | 0.31 |
CV (%) | 5.85 | 4.82 | 4.36 | 6.65 | 5.02 | 3.59 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance