• Mouse DCN (Decorin) CLIA Kit (STJC0001189)

Mouse DCN (Decorin) CLIA Kit (STJC0001189)

SKU:
STJC0001189

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Mouse
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 1.88pg/mL
Detection Limit: 3.13~200pg/mL
Short Description: This mouse DCN kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Dcn
Gene ID: 13179
Uniprot ID: PGS2_MOUSE
Specificity: This kit recognizes Mouse DCN in samples. No significant cross-reactivity or interference between Mouse DCN and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications The attached glycosaminoglycan chain can be either chondroitin sulfate or dermatan sulfate depending upon the tissue of origin.
Function May affect the rate of fibrils formation.
Protein Name Decorin
Bone Proteoglycan Ii
Pg-S2
Pg40
Database Links Reactome: R-MMU-1474228
Reactome: -MMU-1971475
Reactome: -MMU-2022870
Reactome: -MMU-2022923
Reactome: -MMU-2024101
Reactome: -MMU-3000178
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Alternative CLIA Names Decorin CLIA kit
Bone Proteoglycan Ii CLIA kit
Pg-S2 CLIA kit
Pg40 CLIA kit
Dcn CLIA kit
Specificity This kit recognizes Mouse DCN in samples. No significant cross-reactivity or interference between Mouse DCN and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 96-109 102
EDTA plasma(n=8) 85-99 92
Cell culture media(n=8) 85-101 92

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 10.18 24.43 94.61 10.56 25.07 92.37
Standard deviation 1.10 2.30 7.69 1.34 1.83 10.05
CV (%) 10.81 9.41 8.13 12.69 7.30 10.88
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance