• Human XCL1 (Lymphotactin) CLIA Kit (STJC0000755)

Human XCL1 (Lymphotactin) CLIA Kit (STJC0000755)

SKU:
STJC0000755

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This human XCL1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: XCL1
Gene ID: 6375
Uniprot ID: XCL1_HUMAN
Specificity: This kit recognizes Human Lptn/XCL1 in samples. No significant cross-reactivity or interference between Human Lptn/XCL1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Highest level in spleen, lower in peripheral leukocytes and very low levels in lung, colon and small intestine.
Function Chemotactic activity for lymphocytes but not for monocytes or neutrophils. In thymus, mediates medullary accumulation of thymic dendritic cells and contributes to regulatoy T cell development, playing a role in self-tolerance establishment.
Protein Name Lymphotactin
Atac
C Motif Chemokine 1
Cytokine Scm-1
Lymphotaxin
Scm-1-Alpha
Small-Inducible Cytokine C1
Xc Chemokine Ligand 1
Database Links Reactome: R-HSA-380108
Reactome: R-HSA-416476
Cellular Localisation Secreted
Alternative CLIA Names Lymphotactin CLIA kit
Atac CLIA kit
C Motif Chemokine 1 CLIA kit
Cytokine Scm-1 CLIA kit
Lymphotaxin CLIA kit
Scm-1-Alpha CLIA kit
Small-Inducible Cytokine C1 CLIA kit
Xc Chemokine Ligand 1 CLIA kit
XCL1 CLIA kit
LTN CLIA kit
SCYC1 CLIA kit
Specificity This kit recognizes Human Lptn/XCL1 in samples. No significant cross-reactivity or interference between Human Lptn/XCL1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 101-115 108
EDTA plasma(n=8) 89-100 95
Cell culture media(n=8) 87-102 93

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 47.22 108.63 402.71 49.20 100.74 428.50
Standard deviation 5.88 11.47 44.54 5.29 9.29 48.55
CV (%) 12.45 10.56 11.06 10.75 9.22 11.33
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance