• Human UBAP2 (Ubiquitin-associated protein 2) CLIA Kit (STJC0000966)

Human UBAP2 (Ubiquitin-associated protein 2) CLIA Kit (STJC0000966)

SKU:
STJC0000966

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This human UBAP2 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: UBAP2
Gene ID: 55833
Uniprot ID: UBAP2_HUMAN
Specificity: This kit recognizes Human UBAP2 in samples. No significant cross-reactivity or interference between Human UBAP2 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Recruits the ubiquitination machinery to RNA polymerase II for polyubiquitination, removal and degradation, when the transcription-coupled nucleotide excision repair (TC-NER) machinery fails to resolve DNA damage. May promote the degradation of ANXA2.
Protein Name Ubiquitin-Associated Protein 2
Ubap-2
Rna Polymerase Ii Degradation Factor Ubap2
Cellular Localisation Nucleus
Chromosome
Cytoplasm
Associates With Nuclear Chromatin
Alternative CLIA Names Ubiquitin-Associated Protein 2 CLIA kit
Ubap-2 CLIA kit
Rna Polymerase Ii Degradation Factor Ubap2 CLIA kit
UBAP2 CLIA kit
KIAA1491 CLIA kit
Specificity This kit recognizes Human UBAP2 in samples. No significant cross-reactivity or interference between Human UBAP2 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 85-97 92
EDTA plasma(n=8) 94-110 101
Cell culture media(n=8) 92-107 99

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 185.96 638.23 1801.86 184.71 633.25 1830.49
Standard deviation 15.43 71.29 114.96 15.70 69.47 131.43
CV (%) 8.30 11.17 6.38 8.50 10.97 7.18
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance