Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.09ng/mL |
Detection Limit: |
0.16~10ng/mL |
Short Description: |
This human TYR kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
TYR |
Gene ID: |
7299 |
Uniprot ID: |
TYRO_HUMAN |
Specificity: |
This kit recognizes Human TYR in samples. No significant cross-reactivity or interference between Human TYR and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Post Translational Modifications | Glycosylated. |
Function | This is a copper-containing oxidase that functions in the formation of pigments such as melanins and other polyphenolic compounds. Catalyzes the initial and rate limiting step in the cascade of reactions leading to melanin production from tyrosine. In addition to hydroxylating tyrosine to DOPA (3,4-dihydroxyphenylalanine), also catalyzes the oxidation of DOPA to DOPA-quinone, and possibly the oxidation of DHI (5,6-dihydroxyindole) to indole-5,6 quinone. |
Protein Name | TyrosinaseLb24-AbMonophenol MonooxygenaseSk29-AbTumor Rejection Antigen Ab |
Database Links | Reactome: R-HSA-5662702 |
Cellular Localisation | Melanosome MembraneSingle-Pass Type I Membrane ProteinMelanosomeProper Trafficking To Melanosome Is Regulated By Sgsm2Ankrd27Rab9aRab32 And Rab38 |
Alternative CLIA Names | Tyrosinase CLIA kitLb24-Ab CLIA kitMonophenol Monooxygenase CLIA kitSk29-Ab CLIA kitTumor Rejection Antigen Ab CLIA kitTYR CLIA kit |
Specificity | This kit recognizes Human TYR in samples. No significant cross-reactivity or interference between Human TYR and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 97-113 | 103 |
EDTA plasma(n=8) | 85-98 | 92 |
Cell culture media(n=8) | 96-113 | 104 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 0.52 | 1.33 | 3.90 | 0.52 | 1.34 | 4.09 |
Standard deviation | 0.07 | 0.10 | 0.31 | 0.06 | 0.10 | 0.27 |
CV (%) | 13.46 | 7.52 | 7.95 | 11.54 | 7.46 | 6.60 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance