Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
7.5pg/mL |
Detection Limit: |
12.5~800pg/mL |
Short Description: |
This human TNNI1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
TNNI1 |
Gene ID: |
7135 |
Uniprot ID: |
TNNI1_HUMAN |
Specificity: |
This kit recognizes Human TNNI1 in samples. No significant cross-reactivity or interference between Human TNNI1 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Highest levels observed in human skeletal muscle (e.g. gastrocnemious muscle), differentiated cultures of primary human muscle cells and rhabdomyosarcoma cells cultured in low serum medium. Expressed in C2 muscle cell myoblasts and myotubes. |
Function | Troponin I is the inhibitory subunit of troponin, the thin filament regulatory complex which confers calcium-sensitivity to striated muscle actomyosin ATPase activity. |
Protein Name | Troponin I - Slow Skeletal MuscleTroponin I - Slow-Twitch Isoform |
Database Links | Reactome: R-HSA-390522 |
Alternative CLIA Names | Troponin I - Slow Skeletal Muscle CLIA kitTroponin I - Slow-Twitch Isoform CLIA kitTNNI1 CLIA kit |
Specificity | This kit recognizes Human TNNI1 in samples. No significant cross-reactivity or interference between Human TNNI1 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 92-104 | 98 |
EDTA plasma(n=8) | 92-104 | 98 |
Cell culture media(n=8) | 92-107 | 98 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 42.46 | 74.06 | 296.59 | 43.42 | 78.52 | 283.01 |
Standard deviation | 3.40 | 5.90 | 19.34 | 3.50 | 7.97 | 31.53 |
CV (%) | 8.01 | 7.97 | 6.52 | 8.06 | 10.15 | 11.14 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance