• Human TFF3 (Trefoil factor 3) CLIA Kit (STJC0000526)

Human TFF3 (Trefoil factor 3) CLIA Kit (STJC0000526)

SKU:
STJC0000526

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This human TFF3 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: TFF3
Gene ID: 7033
Uniprot ID: TFF3_HUMAN
Specificity: This kit recognizes Human TFF3 in samples. No significant cross-reactivity or interference between Human TFF3 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed in goblet cells of the intestines and colon (at protein level). Expressed by goblet cells of small and large intestinal epithelia and also by the uterus. Also expressed in the hypothalamus where it is detected in paraventricular, periventricular and supraoptic nuclei (at protein level).
Function Involved in the maintenance and repair of the intestinal mucosa. Promotes the mobility of epithelial cells in healing processes (motogen).
Protein Name Trefoil Factor 3
Intestinal Trefoil Factor
Hitf
Polypeptide P1.B
Hp1.B
Database Links Reactome: R-HSA-9018519
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Cytoplasm
Alternative CLIA Names Trefoil Factor 3 CLIA kit
Intestinal Trefoil Factor CLIA kit
Hitf CLIA kit
Polypeptide P1.B CLIA kit
Hp1.B CLIA kit
TFF3 CLIA kit
ITF CLIA kit
TFI CLIA kit
Specificity This kit recognizes Human TFF3 in samples. No significant cross-reactivity or interference between Human TFF3 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 99-116 107
EDTA plasma(n=8) 88-101 93
Cell culture media(n=8) 93-103 98

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 48.19 148.02 364.57 52.37 140.58 373.33
Standard deviation 5.46 15.66 37.59 5.22 13.59 24.08
CV (%) 11.33 10.58 10.31 9.97 9.67 6.45
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance