Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
18.75pg/mL |
Detection Limit: |
31.25~2000pg/mL |
Short Description: |
This human SYCN kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
SYCN |
Gene ID: |
342898 |
Uniprot ID: |
SYCN_HUMAN |
Specificity: |
This kit recognizes Human SYCN in samples. No significant cross-reactivity or interference between Human SYCN and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Post Translational Modifications | Contains intrachain disulfide bonds. |
Function | Functions in exocytosis in pancreatic acinar cells regulating the fusion of zymogen granules with each other. May have a pore-forming activity on membranes and regulate exocytosis in other exocrine tissues. |
Protein Name | SyncollinInsulin Synthesis-Associated Protein 1 |
Cellular Localisation | Zymogen Granule MembranePeripheral Membrane ProteinLumenal SideZymogen Granule LumenAssociated In A Cholesterol-Dependent Manner With Lipid Rafts Of Zymogen Granule Membranes |
Alternative CLIA Names | Syncollin CLIA kitInsulin Synthesis-Associated Protein 1 CLIA kitSYCN CLIA kitINSSA1 CLIA kitSYL CLIA kit |
Specificity | This kit recognizes Human SYCN in samples. No significant cross-reactivity or interference between Human SYCN and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 95-110 | 100 |
EDTA plasma(n=8) | 93-104 | 98 |
Cell culture media(n=8) | 89-101 | 96 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 102.54 | 273.36 | 794.56 | 111.10 | 246.35 | 808.74 |
Standard deviation | 12.41 | 31.05 | 86.29 | 12.80 | 19.71 | 55.80 |
CV (%) | 12.10 | 11.36 | 10.86 | 11.52 | 8.00 | 6.90 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance