Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.09ng/mL |
Detection Limit: |
0.16~10ng/mL |
Short Description: |
This human PROCR kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
PROCR |
Gene ID: |
10544 |
Uniprot ID: |
EPCR_HUMAN |
Specificity: |
This kit recognizes Human EPCR in samples. No significant cross-reactivity or interference between Human EPCR and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Expressed strongly in the endothelial cells of arteries and veins in heart and lung, less intensely in capillaries in the lung and skin, and not at all in the endothelium of small vessels of the liver and kidney. |
Post Translational Modifications | N-glycosylated. A soluble form exists.probably released by a metalloprotease. Seems to have the same activity as the membrane-bound form. |
Function | Binds activated protein C. Enhances protein C activation by the thrombin-thrombomodulin complex.plays a role in the protein C pathway controlling blood coagulation. |
Protein Name | Endothelial Protein C ReceptorActivated Protein C ReceptorApc ReceptorEndothelial Cell Protein C ReceptorCd Antigen Cd201 |
Database Links | Reactome: R-HSA-140875Reactome: R-HSA-202733 |
Cellular Localisation | MembraneSingle-Pass Type I Membrane Protein |
Alternative CLIA Names | Endothelial Protein C Receptor CLIA kitActivated Protein C Receptor CLIA kitApc Receptor CLIA kitEndothelial Cell Protein C Receptor CLIA kitCd Antigen Cd201 CLIA kitPROCR CLIA kitEPCR CLIA kit |
Specificity | This kit recognizes Human EPCR in samples. No significant cross-reactivity or interference between Human EPCR and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 85-100 | 91 |
EDTA plasma(n=8) | 97-113 | 105 |
Cell culture media(n=8) | 86-99 | 91 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 0.54 | 1.09 | 4.46 | 0.57 | 0.99 | 4.37 |
Standard deviation | 0.07 | 0.08 | 0.28 | 0.06 | 0.10 | 0.37 |
CV (%) | 12.96 | 7.34 | 6.28 | 10.53 | 10.10 | 8.47 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance