• Human PLAT (Tissue-type plasminogen activator) CLIA Kit (STJC0000888)

Human PLAT (Tissue-type plasminogen activator) CLIA Kit (STJC0000888)

SKU:
STJC0000888

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 75pg/mL
Detection Limit: 125~8000pg/mL
Short Description: This human PLAT kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: PLAT
Gene ID: 5327
Uniprot ID: TPA_HUMAN
Specificity: This kit recognizes Human tPA in samples. No significant cross-reactivity or interference between Human tPA and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Synthesized in numerous tissues (including tumors) and secreted into most extracellular body fluids, such as plasma, uterine fluid, saliva, gingival crevicular fluid, tears, seminal fluid, and milk.
Post Translational Modifications The single chain, almost fully active enzyme, can be further processed into a two-chain fully active form by a cleavage after Arg-310 catalyzed by plasmin, tissue kallikrein or factor Xa. Differential cell-specific N-linked glycosylation gives rise to two glycoforms, type I (glycosylated at Asn-219) and type II (not glycosylated at Asn-219). The single chain type I glycoform is less readily converted into the two-chain form by plasmin, and the two-chain type I glycoform has a lower activity than the two-chain type II glycoform in the presence of fibrin. N-glycosylation of Asn-152.the bound oligomannosidic glycan is involved in the interaction with the mannose receptor. Characterization of O-linked glycan was studied in Bowes melanoma cell line.
Function Converts the abundant, but inactive, zymogen plasminogen to plasmin by hydrolyzing a single Arg-Val bond in plasminogen. By controlling plasmin-mediated proteolysis, it plays an important role in tissue remodeling and degradation, in cell migration and many other physiopathological events. During oocyte activation, plays a role in cortical granule reaction in the zona reaction, which contributes to the block to polyspermy.
Protein Name Tissue-Type Plasminogen Activator
T-Pa
T-Plasminogen Activator
Tpa
Alteplase
Reteplase Cleaved Into - Tissue-Type Plasminogen Activator Chain A - Tissue-Type Plasminogen Activator Chain B
Database Links Reactome: R-HSA-186797
Reactome: R-HSA-75205
Cellular Localisation Secreted
Extracellular Space
Alternative CLIA Names Tissue-Type Plasminogen Activator CLIA kit
T-Pa CLIA kit
T-Plasminogen Activator CLIA kit
Tpa CLIA kit
Alteplase CLIA kit
Reteplase Cleaved Into - Tissue-Type Plasminogen Activator Chain A - Tissue-Type Plasminogen Activator Chain B CLIA kit
PLAT CLIA kit
Specificity This kit recognizes Human tPA in samples. No significant cross-reactivity or interference between Human tPA and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 98-114 104
EDTA plasma(n=8) 92-108 100
Cell culture media(n=8) 94-108 100

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 368.54 1241.54 3545.67 345.98 1320.62 3302.68
Standard deviation 36.96 123.66 281.53 41.93 123.61 352.07
CV (%) 10.03 9.96 7.94 12.12 9.36 10.66
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance