Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
37.5pg/mL |
Detection Limit: |
62.5~4000pg/mL |
Short Description: |
This human MT2A kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
MT2A |
Gene ID: |
4502 |
Uniprot ID: |
MT2_HUMAN |
Specificity: |
This kit recognizes Human MT2 in samples. No significant cross-reactivity or interference between Human MT2 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Function | Metallothioneins have a high content of cysteine residues that bind various heavy metals.these proteins are transcriptionally regulated by both heavy metals and glucocorticoids. |
Protein Name | Metallothionein-2Mt-2Metallothionein-2aMetallothionein-IiMt-Ii |
Database Links | Reactome: R-HSA-5661231Reactome: R-HSA-877300 |
Alternative CLIA Names | Metallothionein-2 CLIA kitMt-2 CLIA kitMetallothionein-2a CLIA kitMetallothionein-Ii CLIA kitMt-Ii CLIA kitMT2A CLIA kitCES1 CLIA kitMT2 CLIA kit |
Specificity | This kit recognizes Human MT2 in samples. No significant cross-reactivity or interference between Human MT2 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 101-113 | 107 |
EDTA plasma(n=8) | 88-103 | 95 |
Cell culture media(n=8) | 90-100 | 95 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 192.21 | 637.06 | 1964.61 | 203.91 | 601.67 | 1997.49 |
Standard deviation | 16.88 | 46.57 | 163.06 | 16.48 | 71.30 | 182.37 |
CV (%) | 8.78 | 7.31 | 8.30 | 8.08 | 11.85 | 9.13 |