• Human MMP7 (Matrilysin) CLIA Kit (STJC0000649)

Human MMP7 (Matrilysin) CLIA Kit (STJC0000649)

SKU:
STJC0000649

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human MMP7 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: MMP7
Gene ID: 4316
Uniprot ID: MMP7_HUMAN
Specificity: This kit recognizes Human MMP-7 in samples. No significant cross-reactivity or interference between Human MMP-7 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Degrades casein, gelatins of types I, III, IV, and V, and fibronectin. Activates procollagenase.
Protein Name Matrilysin
Matrin
Matrix Metalloproteinase-7
Mmp-7
Pump-1 Protease
Uterine Metalloproteinase
Database Links Reactome: R-HSA-1442490
Reactome: R-HSA-1474228
Reactome: R-HSA-1592389
Reactome: R-HSA-2022090
Reactome: R-HSA-9009391
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Alternative CLIA Names Matrilysin CLIA kit
Matrin CLIA kit
Matrix Metalloproteinase-7 CLIA kit
Mmp-7 CLIA kit
Pump-1 Protease CLIA kit
Uterine Metalloproteinase CLIA kit
MMP7 CLIA kit
MPSL1 CLIA kit
PUMP1 CLIA kit
Specificity This kit recognizes Human MMP-7 in samples. No significant cross-reactivity or interference between Human MMP-7 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 97-113 105
EDTA plasma(n=8) 96-111 101
Cell culture media(n=8) 88-101 95

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 108.25 234.86 780.93 101.74 248.78 729.80
Standard deviation 11.40 20.01 80.98 11.16 20.90 66.56
CV (%) 10.53 8.52 10.37 10.97 8.40 9.12
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance