Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
18.75pg/mL |
Detection Limit: |
31.25~2000pg/mL |
Short Description: |
This human MMP17 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
MMP17 |
Gene ID: |
4326 |
Uniprot ID: |
MMP17_HUMAN |
Specificity: |
This kit recognizes Human MMP-17 in samples. No significant cross-reactivity or interference between Human MMP-17 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Expressed in brain, leukocytes, colon, ovary testis and breast cancer. Expressed also in many transformed and non-transformed cell types. |
Post Translational Modifications | The precursor is cleaved by a furin endopeptidase. |
Function | Endopeptidase that degrades various components of the extracellular matrix, such as fibrin. May be involved in the activation of membrane-bound precursors of growth factors or inflammatory mediators, such as tumor necrosis factor-alpha. May also be involved in tumoral process. Cleaves pro-TNF-alpha at the '74-Ala-|-Gln-75' site. Not obvious if able to proteolytically activate progelatinase A. Does not hydrolyze collagen types I, II, III, IV and V, gelatin, fibronectin, laminin, decorin nor alpha1-antitrypsin. |
Protein Name | Matrix Metalloproteinase-17Mmp-17Membrane-Type Matrix Metalloproteinase 4Mt-Mmp 4Mtmmp4Membrane-Type-4 Matrix MetalloproteinaseMt4-MmpMt4mmp |
Database Links | Reactome: R-HSA-1592389 |
Cellular Localisation | Isoform Long: Cell MembraneLipid-AnchorGpi-AnchorExtracellular SideSecretedExtracellular SpaceExtracellular Matrix |
Alternative CLIA Names | Matrix Metalloproteinase-17 CLIA kitMmp-17 CLIA kitMembrane-Type Matrix Metalloproteinase 4 CLIA kitMt-Mmp 4 CLIA kitMtmmp4 CLIA kitMembrane-Type-4 Matrix Metalloproteinase CLIA kitMt4-Mmp CLIA kitMt4mmp CLIA kitMMP17 CLIA kitMT4MMP CLIA kit |
Specificity | This kit recognizes Human MMP-17 in samples. No significant cross-reactivity or interference between Human MMP-17 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 89-102 | 94 |
EDTA plasma(n=8) | 92-105 | 98 |
Cell culture media(n=8) | 96-114 | 104 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 97.10 | 299.90 | 867.30 | 91.95 | 282.03 | 946.19 |
Standard deviation | 12.45 | 22.85 | 91.76 | 8.36 | 26.26 | 64.15 |
CV (%) | 12.82 | 7.62 | 10.58 | 9.09 | 9.31 | 6.78 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance