• Human MMP10 (Stromelysin-2) CLIA Kit (STJC0000112)

Human MMP10 (Stromelysin-2) CLIA Kit (STJC0000112)

SKU:
STJC0000112

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human MMP10 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: MMP10
Gene ID: 4319
Uniprot ID: MMP10_HUMAN
Specificity: This kit recognizes Human MMP-10 in samples. No significant cross-reactivity or interference between Human MMP-10 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Can degrade fibronectin, gelatins of type I, III, IV, and V.weakly collagens III, IV, and V. Activates procollagenase.
Protein Name Stromelysin-2
Sl-2
Matrix Metalloproteinase-10
Mmp-10
Transin-2
Database Links Reactome: R-HSA-1442490
Reactome: R-HSA-1474228
Reactome: R-HSA-1592389
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Alternative CLIA Names Stromelysin-2 CLIA kit
Sl-2 CLIA kit
Matrix Metalloproteinase-10 CLIA kit
Mmp-10 CLIA kit
Transin-2 CLIA kit
MMP10 CLIA kit
STMY2 CLIA kit
Specificity This kit recognizes Human MMP-10 in samples. No significant cross-reactivity or interference between Human MMP-10 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-104 99
EDTA plasma(n=8) 91-107 97
Cell culture media(n=8) 88-99 94

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 108.66 266.38 764.49 106.35 249.38 782.07
Standard deviation 12.80 27.20 50.92 8.74 27.71 63.66
CV (%) 11.78 10.21 6.66 8.22 11.11 8.14
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance