• Human MGP (Matrix Gla protein) CLIA Kit (STJC0000641)

Human MGP (Matrix Gla protein) CLIA Kit (STJC0000641)

SKU:
STJC0000641

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 4.69pg/mL
Detection Limit: 7.81~500pg/mL
Short Description: This human MGP kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: MGP
Gene ID: 4256
Uniprot ID: MGP_HUMAN
Specificity: This kit recognizes Human MGP in samples. No significant cross-reactivity or interference between Human MGP and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications Requires vitamin K-dependent gamma-carboxylation for its function.
Function Associates with the organic matrix of bone and cartilage. Thought to act as an inhibitor of bone formation.
Protein Name Matrix Gla Protein
Mgp
Cell Growth-Inhibiting Gene 36 Protein
Cellular Localisation Secreted
Alternative CLIA Names Matrix Gla Protein CLIA kit
Mgp CLIA kit
Cell Growth-Inhibiting Gene 36 Protein CLIA kit
MGP CLIA kit
MGLAP CLIA kit
GIG36 CLIA kit
Specificity This kit recognizes Human MGP in samples. No significant cross-reactivity or interference between Human MGP and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 85-96 91
EDTA plasma(n=8) 88-101 94
Cell culture media(n=8) 86-97 92

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 22.89 79.32 204.58 22.05 86.53 219.41
Standard deviation 2.63 9.26 21.17 2.10 9.82 18.32
CV (%) 11.49 11.67 10.35 9.52 11.35 8.35
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance