• Human MELTF (Melanotransferrin) CLIA Kit (STJC0000977)

Human MELTF (Melanotransferrin) CLIA Kit (STJC0000977)

SKU:
STJC0000977

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This human MELTF kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: MELTF
Gene ID: 4241
Uniprot ID: TRFM_HUMAN
Specificity: This kit recognizes Human MFI2 in samples. No significant cross-reactivity or interference between Human MFI2 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Found predominantly in human melanomas and in certain fetal tissues.also found in liver, epithelium, umbilical chord, placenta and sweat gland ducts.
Function Involved in iron cellular uptake. Seems to be internalized and then recycled back to the cell membrane. Binds a single atom of iron per subunit. Could also bind zinc.
Protein Name Melanotransferrin
Melanoma-Associated Antigen P97
Cd Antigen Cd228
Database Links Reactome: R-HSA-163125
Reactome: R-HSA-381426
Reactome: R-HSA-8957275
Cellular Localisation Isoform 1: Cell Membrane
Lipid-Anchor
Gpi-Anchor
Alternative CLIA Names Melanotransferrin CLIA kit
Melanoma-Associated Antigen P97 CLIA kit
Cd Antigen Cd228 CLIA kit
MELTF CLIA kit
MAP97 CLIA kit
MFI2 CLIA kit
Specificity This kit recognizes Human MFI2 in samples. No significant cross-reactivity or interference between Human MFI2 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-109 100
EDTA plasma(n=8) 98-112 104
Cell culture media(n=8) 85-101 92

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 48.11 117.57 485.24 51.47 127.97 446.54
Standard deviation 5.51 12.16 31.10 6.26 13.41 38.89
CV (%) 11.45 10.34 6.41 12.16 10.48 8.71
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance