• Human LRP6 (Low-density lipoprotein receptor-related protein 6) CLIA Kit (STJC0000553)

Human LRP6 (Low-density lipoprotein receptor-related protein 6) CLIA Kit (STJC0000553)

SKU:
STJC0000553

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This human LRP6 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: LRP6
Gene ID: 4040
Uniprot ID: LRP6_HUMAN
Specificity: This kit recognizes Human LRP6 in samples. No significant cross-reactivity or interference between Human LRP6 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Widely coexpressed with LRP5 during embryogenesis and in adult tissues.
Post Translational Modifications Dual phosphorylation of cytoplasmic PPPSP motifs sequentially by GSK3 and CK1 is required for AXIN1-binding, and subsequent stabilization and activation of beta-catenin via preventing GSK3-mediated phosphorylation of beta-catenin. Phosphorylated, in vitro, by GRK5/6 within and outside the PPPSP motifs. Phosphorylation at Ser-1490 by CDK14 during G2/M phase leads to regulation of the Wnt signaling pathway during the cell cycle. Phosphorylation by GSK3B is induced by RPSO1 binding and inhibited by DKK1. Phosphorylated, in vitro, by casein kinase I on Thr-1479. Undergoes gamma-secretase-dependent regulated intramembrane proteolysis (RIP). The extracellular domain is first released by shedding, and then, through the action of gamma-secretase, the intracellular domain (ICD) is released into the cytoplasm where it is free to bind to GSK3B and to activate canonical Wnt signaling. Palmitoylation on the two sites near the transmembrane domain leads to release of LRP6 from the endoplasmic reticulum. Mono-ubiquitinated which retains LRP6 in the endoplasmic reticulum. Ubiquitinated by ZNRF3, leading to its degradation by the proteasome. N-glycosylation is required for cell surface location.
Function Component of the Wnt-Fzd-LRP5-LRP6 complex that triggers beta-catenin signaling through inducing aggregation of receptor-ligand complexes into ribosome-sized signalosomes. Cell-surface coreceptor of Wnt/beta-catenin signaling, which plays a pivotal role in bone formation. The Wnt-induced Fzd/LRP6 coreceptor complex recruits DVL1 polymers to the plasma membrane which, in turn, recruits the AXIN1/GSK3B-complex to the cell surface promoting the formation of signalosomes and inhibiting AXIN1/GSK3-mediated phosphorylation and destruction of beta-catenin. Required for posterior patterning of the epiblast during gastrulation.
Protein Name Low-Density Lipoprotein Receptor-Related Protein 6
Lrp-6
Database Links Reactome: R-HSA-201681
Reactome: R-HSA-3772470
Reactome: R-HSA-4641262
Reactome: R-HSA-4641263
Reactome: R-HSA-5340588
Cellular Localisation Cell Membrane
Single-Pass Type I Membrane Protein
Endoplasmic Reticulum
Membrane Raft
On Wnt Signaling
Undergoes A Cycle Of Caveolin- Or Clathrin-Mediated Endocytosis And Plasma Membrane Location
Released From The Endoplasmic Reticulum On Palmitoylation
Mono-Ubiquitination Retains It In The Endoplasmic Reticulum In The Absence Of Palmitoylation
Phosphorylated
Aggregates And Colocalizes With Axin1 And Gsk3b At The Plasma Membrane In Lrp6-Signalosomes
Chaperoned To The Plasma Membrane By Mesd
Alternative CLIA Names Low-Density Lipoprotein Receptor-Related Protein 6 CLIA kit
Lrp-6 CLIA kit
LRP6 CLIA kit
Specificity This kit recognizes Human LRP6 in samples. No significant cross-reactivity or interference between Human LRP6 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 95-107 100
EDTA plasma(n=8) 86-99 92
Cell culture media(n=8) 89-102 95

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 219.26 413.78 1933.85 207.02 383.82 1917.28
Standard deviation 19.27 47.71 150.84 25.82 31.32 162.78
CV (%) 8.79 11.53 7.80 12.47 8.16 8.49
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance